A, model steel window production quality inspection standards 
1 model steel window surface should be smooth, the color should be uniform, no crack, no bubbles, welding cleaned rules, may have affect the use of impurities such as defects. The average Angle. 
2 outdoor window should have sink, length of 25 mm, groove to straight, can't will play through the profiles below. Ensure the timely and emitted into the box water, and dust prevention effect. 
3 window frame window wide to allow the high dimension deviation, 2 meters below the Windows and doors should be not more than + 3 mm, 2 meters above the doors and Windows should be not more than + 3.5 mm. 
Four frames of the difference of the diagonal dimension of the door, the allowable deviation (300 mm to 300 mm) + 2.0 mm or less, (901 mm to 901 mm) + 2.5 mm or less, (1502 mm to 1502 mm) + 3.0 mm or less. 
5 two adjacent component assembly clearance is less than 0.5 mm, the same flatness, between two component welds shall not be greater than 0.8 mm. 
6 glass bead under the Angle, the gap should not be greater than 1 mm, assembly and firm, not to use two root bead on one side. 
7 hardware fittings installed correctly, complete quantity, installation is firm, flexible switch, and have enough strength. 
Article 8 seal should be even and firm, after assembly interface, no bath. 
9 boxes, fan assembly, shall not interfere with the switch function, door to door should not warp. 
10 each section of fixed, screws shall not be less than 3, the spacing is not more than 300 mm, from steel end should be no greater than 100 mm. After the fixed payments shall not be loose. 
11 glass size, from the pervious to light the edge of the window frame and window sash, take a scoop out not less than 8 mm per side, glaze, must be assembled shock pad around the glass. 
Second, the plastic door quality inspection standards 
1 plastic door surface should be smooth, the color should be basically the same, no crack, no bubbles, smooth weld cleaning rules, shall not affect the use of defects such as scar, impurities. Box and the average Angle of fan strength not less than 3000 n. 
2 doors made of steel and fasteners surface should be antirust processing, the thickness of the steel should be not less than 1.2 mm, fixed each steel fasteners shall not be less than 3, the spacing should be no greater than 300 mm, from steel end should be no greater than 100 mm. After the fixed payments shall not be loose. 
3 door should be sink, make the water in the box into emitted in a timely manner. 
4 the height of the door frame, door leaf margin of error (2 meters) + 2.0 mm or less, (more than 2 m) + 3.5 mm or less 
5 doors diagonal size difference is not more than 3 mm. 
6 door assembling gap should be allowed no more than 0.6 mm. 
7 two adjacent components assembly clearance should be no greater than 0.5 mm, the same flatness between two component welds shall not be greater than 0.8 mm. 
8 hinge door frame and door leaf after assembly parts (not sealing strip when loading) fit clearance of allowable deviation of 1 mm ~ 2 mm. 
Around 9 door frames, door leaf lap width should be uniform, flat open lap over sealing strip the margin of error of 2.5 mm or less, flat open door assembly should be 2 mm high, when sliding door frame, door leaf lap around the amount (more than wool top) the allowable deviation of 3.5 ~ 1.5 mm. 
10 frame and door leaf after assembly and shall not interfere with the switch function, they should not be warp. 
11 hardware accessories installation position should be accurate, the amount should be complete, the installation should be strong. 
Article 12 seal should be evenly after assembly, firm, interface precision, no bath. 
After 13 layering assembly should be firmly. Layering corner parts when it clearance shall be not less than 3 mm. 
14 glass size, from the pervious to light the edge of the door frame, door leaf, each side should be no less than 8 mm. Around the glass, the glass must be assembled shock block. 
Three, the installation of window of model steel door standards 
1 in order to guarantee the quality of window of model steel door installation, standard rules are hereby formulated. This specification applies to the model steel window (including the casement Windows, push-pull window and combination window), plastic door (including swing doors, sliding door) door window installation. 
2 doors and Windows installation quality requirements. 
2.1.1 the installation process used by the Windows components, parts, materials, etc in the process of transportation, storage and construction measures should be taken to prevent its damage and deformation. 
2.1.2 door place should be clean, smooth, and avoid weathered. Shall be made, tilt Angle of not less than 70 °. 
2.1.3 loading and unloading of doors and Windows to should take put down gently, not to pry, fall, hit, not insert prop up lifting in the sash. 
2.1.4 before the installation, should check the number of doors and Windows according to the requirement of the design drawings, varieties, specifications and open direction, doors and Windows hardware, sealing strip, fasteners should be complete, not eligible should be replaced. 
2.2 doors and Windows installation 
2.2.1 fixed installation location should be in conformity with the embedded block, but may not be a fixed piece in a transverse frame, in the mullion, has grown two millimeters spell location, spacing between adjacent stator should be no greater than 600 mm. In addition to the fixed piece, can also be used for expansion bolt, the distance is not more than 600 mm. The location of the special bolts shall be in conformity with the project of embedded block position. 
2.2.2 hang outside the window from top, find out the hole centerline and the window frame line alignment, according to the requirements of the elevation at the same time put in place, the window frame window box up and down the four corners and wedge between temporary fixation. And then adjust the levelness of the window frame vertical degree and the position of the direction of the hole in the wall thickness.